We offer a range of Hall elements featuring a variety of materials and package compositions to meet different customer requirements. Use the following procedure to select the Hall element that best suit your application.
Mode of use for application of Hall element
- Use as a switch.
Ultra-high sensitivity due to the use of magnetic concentrating material.

- Principal applications
- DC brushless motors
- Electric current sensors ( balance type)
- Various switches
(Please prepare the switching circuit separately.)
- Use in analog output
V
Η changes linear with the magnetic flux density.

- Principal applications
- Various analog position sensing
- Electric current sensors (open type)

HQ series
HZ series
HG series

Comparison between HQ, HZ and HG series
In the case of constant voltage drive
| |
Hall output voltage VΗ
(mV/3V, 50 mT) |
Offset voltage ratio Vos/VΗ(*)
(B=0/50mT) |
Temperature coefficient of VΗ
(%/°C) |
| HQ series |
90 to 130 |
<6% |
-0.2 |
| HZ series |
44 to 66 |
<16% |
-0.14 |
| High sensitivity HG series |
39 to 51 |
<10% |
-0.2 |
Normal sensitivity HG series
(HG-106A) |
33 to 42 |
<20% |
-0.2 |
Normal sensitivity HG series
(HG-106C) |
28 to 33 |
<20% |
-0.2 |
|
(*)Normal sensitivity HG and HZ series are converted because they are specified by the offset voltage.
Constant voltage drive
Constant voltage VΗ thermal characteristics of various Hall elements

Constant current drive
| |
Hall output voltage VΗ
(mV/1mA.50mT) |
Offset voltage ratio Vos/VΗ(*)
(B=0/50mT) |
Temperature coefficient of VΗ
(%/°C) |
| HQ series |
Approx. 35 |
<6% |
-0.4 |
| High sensitivity HG series |
Approx. 20 |
<10% |
-0.04 |
| Normal sensitivity HG series |
Approx. 8 |
<20% |
-0.025 |
| HZ series |
Approx. 5 |
<16% |
-0.1 |
|
(*)Normal sensitivity HG and HZ series are converted because they are specified by the offset voltage.
(**)Because the output voltage in the constant current drive is not specified, it is stated as an approximate value.
Constant current VΗ thermal characteristics of various Hall elements