Please use within the maximum rating and under the recommended operating conditions.
Because Hall effect ICs have polarity, take care to avoid reverse connection.
In particular, please take care to avoid high voltage [through][in][on] the element.
The element could be destroyed if the rated range should be exceeded.
Please take measures to protect against surge voltage and static charges in storage, handling, and mounting in a circuit.
Use Hall effect ICs in a manner that does not allow element to make contact with the driving circuit.
Please pay careful attention to the following precautions when carrying out lead forming for Hall effect ICs:
|
Although the reference conditions are shown as follows, please apply them only after careful examination and confirmation by the customer.


Please follow the procedure below when cleaning solder flux etc.
| 1. | Cleaning agent | ... | Ethanol and isopropyl alcohol |
| 2. | Temperature | ... | 50°C or less |
| 3. | When ultrasonic cleaning is employed | ... | Frequency: 45 kHz or less, Power output: 40 W/liter or less |
Please avoid direct sunlight when the products are stored, and keep them at normal room temperature and humidity as far as possible.
(Preferable storage condition is 5°C to 35°C and 40% to 85% RH.)
If the elements are stored for an extended time (two years or more) under the general storage conditions for semiconductors, the soldering characteristics of the lead terminal and the electrical characteristics could deteriorate; therefore, only use such elements after verifying their soldering and electrical characteristics, etc..
We recommend long-term storage in a nitrogen atmosphere.
The lead of the element will be oxidized by the oxygen in the atmosphere, and the soldering characteristics will deteriorate if the elements are stored in a normal atmosphere.